Air – foam apparatuses 136; PN 1.6 MPa

Purpose

The air – foam apparatus is intended for fire extinguishing in machinery spaces on ships by means of foam with ratio 1:64 up to 1: 1000

The air – foam apparatus is mounted onboard by welding of its foundation.

Enclosed documents: working drawing, specification and certificate in Bulgarian, Russian and English.

The air – foam apparatus is painted in red colour.

    Purpose

    The air – foam apparatus is intended for fire extinguishing in machinery spaces on ships by means of foam with ratio 1:64 up to 1: 1000

    The air – foam apparatus is mounted onboard by welding of its foundation.

    Enclosed documents: working drawing, specification and certificate in Bulgarian, Russian and English.

    The air – foam apparatus is painted in red colour.

    Rules for service:

    In case of fire, the hose is united and taken down on floor, the foam generator is taken and the air bottle starting valve is opened. The cock to the foam generator is opened and the obtained foam jet is directed to the centre of the fire in order to cover the flame with foam layer.

    Main technical characteristics:

    Foaming agent Penol M-90Air – foam apparatus
    136 l
    Volume of foaming agent, l9,2
    Volume of water to upper level, l126
    Air pressure in the air bottle, МРа3,0
    Reduced air pressure, МРа1,0
    Safety valve opening pressure, МРа1,65
    Quantity of foam obtained from 1 charge8000
    Operation , min5
    Certificate590-ИК-070

     

    SymbolDrawing numberArticle numberDimensions, mmWeitgh, kg
    123LL1H7
    456
    ВП-136-1,6595-ИК-1018825169205001000375