Boilers For Fresh Water Heating

The boilers are intended to preheat fresh water up to 70÷90 °C.

Depending on the operation principle two constructions are worked out – volume type BOILER 320 and continuous-flow type HEATER EC6/12.

STEAM – ELECTRIC BOILER VOLUME TYPE – BOILER 320

The boiler is intended to preheat fresh water by means of saturated steam or electricity for ship sanitary systems.

    The boilers are intended to preheat fresh water up to 70÷90 °C.

    Depending on the operation principle two constructions are worked out – volume type BOILER 320 and continuous-flow type HEATER EC6/12.

    STEAM – ELECTRIC BOILER VOLUME TYPE – BOILER 320

    The boiler is intended to preheat fresh water by means of saturated steam or electricity for ship sanitary systems.

    The worked out versions of the article include :

    • left or right fastening;
    • version with/without/ heat- insulation;
    • fittings for termosensors G1 OR G½;
    • version only with electric heaters;
    • for general industry purposes.
    Capacity 320 l
    Power of electric heaters 12 kW
    Pressure of heated water 0,8 MPa
    Water temperature  
    inlet 10 0C
    outlet 70 0C
    Steam pressure 0,7 (0,5) MPa
    Capacity for steam heating 0,56 l/s
    Steam consumption 72.10-3
    Capacity for electric heating 0,04 l/s
    Time for boiler volume heating by electric 2,21 h
    Fastening right – side and left – side