Steam Receivers

Steam receivers are intended for use in waste heat recovery systems and ensure the ship with steam for auxiliary needs at running mode. 

    Steam receivers are intended for use in waste heat recovery systems and ensure the ship with steam for auxiliary needs at running mode. 

    Steam receivers work together with exhaust gas boiler with forced circulation and do the following duties: 

    • separate the steam from steam water mixture from EGB; 
    • maintain determined range of the working pressure at changes of steam consumption; 
    • ensure necessary volume for compensation of the possible fluctuations of the water level when starting the cold boiler or at variable conditions of operation. 

    Steam receivers are with automatic or manual control.

     

    Parameter

    Measuring unit

    Numerical value for:

    СПВ1600

    СПВ2500

    Nominal steaming capacity

    кg/h

    1600

    2500

    Nominal working pressure

    МРа

    0,7

    0,7

    Water content up to NWL

    m3

    0,375

    0,77

    Full volume

    m3

    0,875

    1,65